The Hayes command set is a specific command language originally developed by Dennis Hayes for the Hayes Smartmodem 300 baud modem in 1981.
The command set consists of a series of short text strings which can be combined to produce commands for operations such as dialing, hanging up, and changing the parameters of the connection. The vast majority of dial-up modems use the Hayes command set in numerous variations.
The command set covered only those operations supported by the earliest 300 bit/s modems. When new commands were required to control additional functionality in higher speed modems, a variety of one-off standards emerged from each of the major vendors. These continued to share the basic command structure and syntax, but added any number of new commands using some sort of prefix character - &
for Hayes and USR, and \
for Microcom, for instance. Many of these re-standardized on the Hayes extensions after the introduction of the SupraFAXModem 14400 and the subsequent market consolidation that followed.
Video Hayes command set
History
Background
Prior to the introduction of the Bulletin Board System (BBS), modems typically operated on direct-dial telephone lines that always began and ended with a known modem at each end. The modems operated in either "originate" or "answer" modes, manually switching between two sets of frequencies for data transfer. Generally, the user placing the call would switch their modem to "originate" and then dial the number by hand. When the remote modem answered, already set to "answer" mode, the telephone handset was switched off and communications continued until the caller manually disconnected.
When automation was required, it was commonly only needed on the answer side -- for instance, a bank might need to take calls from a number of branch offices for end-of-day processing. To fill this role, some modems included the ability to pick up the phone automatically when it was in answer mode, and clearing the line when the other user manually disconnected. The need for automated outbound dialling was considerably less common, and handled through a separate peripheral device, a "dialler". This was normally plugged into a separate input/output port on the computer (typically an RS-232 port) and programmed separately from the modem itself.
This method of operation worked satisfactorily in the 1960s and early 1970s, when modems were generally used to connect dumb devices like computer terminals (dialling out) with smart mainframe computers (answering). However, the microcomputer revolution of the 1970s led to the introduction of low-cost modems and the idea of a semi-dedicated point-to-point link was no longer appropriate. There were potentially thousands of users who might want to dial any of the other thousands of users, and the only solution at the time was to make the user dial manually.
The computer industry needed a way to tell the modem what number to dial through software. The earlier separate dialers had this capability, but only at the cost of a separate port, which a microcomputer might not have available. Another solution would have been to use a separate set of "command pins" dedicated to sending and receiving commands, another could have used a signal pin indicating that the modem should interpret incoming data as a command. Both of these had hardware support in the RS-232 standard. However, many implementations of the RS-232 port on microcomputers were extremely basic, and some eliminated many of these pins as a cost saving measure.
Hayes' solution
Hayes Communications introduced a solution in its 1981 Smartmodem by re-using the existing data pins with no modification. Instead, the modem itself could switch itself between one of two modes:
- data mode in which the modem sends the data to the remote modem. (A modem in data mode treats everything it receives from the computer as data and sends it across the phone line).
- command mode in which data is interpreted as commands to the local modem (commands that the local modem should execute).
To switch from data mode to command mode, sessions sent an escape sequence string of three plus signs ("+++") followed by a pause of about a second. The pause at the end of the escape sequence was required to reduce the problem caused by in-band signaling: if any other data was received within one second of the three plus signs, it was not the escape sequence and would be sent as data. To switch back they sent the online command, O. In actual use many of the commands automatically switched to the online mode after completion, and it is rare for a user to use the online command explicitly.
In order to avoid licensing Hayes's patent, some manufacturers implemented the escape sequence without the time guard interval (Time Independent Escape Sequence (TIES)). This had a major denial of service security implication in that it would lead to the modem hanging up the connection should the computer ever try to transmit the byte sequence "+++ATH0" in data mode. For any computer connected to the Internet through such a modem, this could be easily exploited by sending it a ping of death request containing the sequence "+++ATH0" in the payload. The computer operating system would automatically try to reply the sender with the same payload, immediately disconnecting itself from the Internet, as the modem would interpret the ICMP packet's data payload as a Hayes command. The same error would also trigger if, for example, the user of the computer ever tried to send an e-mail containing the aforementioned string.
Commands
The Hayes command set includes commands for various phone-line manipulations, dialing and hanging-up for instance. It also includes various controls to set up the modem, including a set of register commands which allowed the user to directly set the various memory locations in the original Hayes modem. The command set was copied largely verbatim, including the meaning of the registers, by almost all early 300 baud modem manufacturers, of which there were quite a few.
The expansion to 1200 and 2400 baud required the addition of a small set of new commands, some of them prefixed with an ampersand ("&") to denote those dedicated to new functionality. Hayes itself was forced to quickly introduce a 2400 baud model shortly after their 1200, and the command sets were identical as a time-saving method. Essentially by accident, this allowed users of existing 1200 baud modems to use the new Hayes 2400 models without changing their software. This re-inforced the use of the Hayes versions of these commands. Years later, the Telecommunications Industry Association (TIA)/Electronic Industries Alliance (EIA) raised the 2400-baud command set into a formal standard with the title Data Transmission Systems and Equipment - Serial Asynchronous Automatic Dialing and Control, TIA/EIA-602.
However, Hayes Communications moved only slowly to higher speeds or the use of compression, and three other companies led the way here -- Microcom, U.S. Robotics and Telebit. Each of these three used its own additional command-sets instead of waiting for Hayes to lead the way. By the early-1990s, there were four major command sets in use, and a number of versions based on one of these. Things became simpler again during the widespread introduction of 14.4 and 28.8 kbit/s modems in the early 1990s. Slowly, a set of commands based heavily on the original Hayes extended set using "&" commands became popular, and then universal. Only one other command set has remained popular, the US Robotics set from their popular line of modems.
Maps Hayes command set
Description
The following text lists part of the Hayes command set (also called the AT commands: "AT" meaning 'attention').
The Hayes command set can subdivide into four groups:
- basic command set - A capital character followed by a digit. For example, M1.
- extended command set - An "&" (ampersand) and a capital character followed by a digit. This extends the basic command set. For example, &M1. Note that M1 is different from &M1.
- proprietary command set - Usually starting either with a backslash ("\") or with a percent sign ("%"); these commands vary widely among modem manufacturers.
- register commands - Sr=n where r is the number of the register to be changed, and n is the new value that is assigned.
A register represents a specific physical location in memory. Modems have small amounts of memory on board. The fourth set of commands serves for entering values into a particular register (memory location). The register will store a particular value (alpha-numeric information) which the modem and the communications software can utilize. For example, S7=60 instructs the modem to "Set register #7 to the value 60".
Although the command-set syntax defines most commands by a letter-number combination (L0, L1 etc.), the use of a zero is optional. In this example, "L0" equates to a plain "L". Keep this in mind when reading the table below.
When in data mode, an escape sequence can return the modem to command mode. The normal escape sequence is three plus signs ("+++"), and to disambiguate it from possible real data, a guard timer is used: it must be preceded by a pause, not have any pauses between the plus signs, and be followed by a pause; by default, a "pause" is one second and "no pause" is anything less.
Syntactical definitions
The following syntactical definitions apply:
- <CR> Carriage return character, is the command line and result code terminator character, which value, in decimal ASCII between 0 and 255, is specified in register S3. The default value is 13.
- <LF> Linefeed character, is the character recognised as line feed character. Its value, in decimal ASCII between 0 and 255, is specified in register S4. The default value is 10. The line feed character is output after the carriage return character if verbose result codes are used (V1 option is used); otherwise, if numeric format result codes are used (V0 option is used), it will not appear in the result codes.
- <...> Name enclosed in angle brackets is a syntactical element. They do not appear in the command line.
- [...] Optional subparameter of a command or an optional part of AT information response is enclosed in square brackets. Brackets themselves do not appear in the command line. When the subparameter is not given in AT commands which have a Read command, the new value equals its previous value. In AT commands which do not store the values of any of their subparameters, and so have not a Read command, which are called action type commands, the action should be done on the basis of the recommended default setting of the subparameter.
Modem initialization
A string can contain many Hayes commands placed together, so as to optimally prepare the modem to dial out or answer, e.g. AT&F&D2&C1S0=0X4
. This is called the initialization string. The V.250 specification requires all DCEs to accept a body (after "AT") of at least 40 characters of concatenated commands.
Example session
The following represents two computers, computer A and computer B, both with modems attached, and the user controlling the modems with terminal-emulator software. Terminal-emulator software typically allows the user to send Hayes commands directly to the modem, and to see the responses. In this example, the user of computer A makes the modem dial the phone number of modem B at phone number 555-1234 (long distance). After every command and response, there is a carriage return sent to complete the command.
Compatibility
While the original Hayes command set represented a huge leap forward in modem-based communications, with time many problems set in, almost none of them due to Hayes per se:
- Due to the lack of a written standard, other modem manufacturers just copied the external visible commands and (roughly) the basic actions. This led to a wide variety of subtle differences in how modems changed from state to state, and how they handled error conditions, hangups, and timeouts.
- Each manufacturer tended to add new commands to handle emerging needs, often incompatible with other modems. For example, setting up hardware or software handshaking often required many different commands for different modems. This undermined the handy universality of the basic Hayes command set.
- Many Hayes compatible modems had serious quirks that made them effectively incompatible. For example, many modems required a pause of several seconds after receiving the "AT Z" reset command. Some modems required spaces between commands, while others did not. Some would unhelpfully change baud-rate of their own volition, which would leave the computer with no clue how to handle the incoming data.
As a result of all this, eventually many communications programs had to give up any sense of being able to talk to all "Hayes-compatible" modems, and instead the programs had to try to determine the modem type from its responses, or provide the user with some option whereby they could enter whatever special commands it took to coerce their particular modem into acting properly.
Autobaud
The Hayes command set facilitated automatic baud rate detection as "A" and "T" happen to have bit patterns that are very regular; "A" is "100 0001" and so has a 1 bit at the start and end and "T" is "101 0100" which has a pattern with (nearly) every other bit set. Since the RS-232 interface transmits least significant bit first, the according line pattern with 8-N-1 (eight data bits, no parity bit, one stop bit) is 11000001011001010101 (start and stop bits italicized) which is used as syncword.
The basic Hayes command set
The following commands are understood by virtually all modems supporting an AT command set, whether old or new.
Note: a command string is terminated with a CR (\r) character
Although not part of the command set, a tilde character ~ is commonly used in modem command sequences. The ~ causes many applications to pause sending the command stream to the device (usually for half a second), e.g. after a Reset. The ~ is not sent to the modem.
Modem S register definitions
V.250
The ITU-T established a standard in its V-Series Recommendations, V.25 ter, in 1995 in an attempt to establish a standard for the command set again. It was renamed V.250 in 1998 with an annex that was not concerning the Hayes command set renamed as V.251. A V.250 compliant modem implements the A, D, E, H, I, L, M, N, O, P, Q, T, V, X, Z, &C, &D, and &F commands in the way specified by the standard. It must also implement S registers and must use registers S0, S3, S4, S5, S6, S7, S8, and S10 for the purposes given in the standard. It also must implement any command beginning with the plus sign, "+" followed by any letter A to Z, only in accordance with ITU recommendations. Modem manufacturers are free to implement other commands and S-registers as they see fit, and may add options to standard commands.
GSM
The ETSI GSM 07.07 (3GPP TS 27.007) specifies AT style commands for controlling a GSM phone or modem. The ETSI GSM 07.05 (3GPP TS 27.005) specifies AT style commands for managing the Short Message Service (SMS) feature of GSM.
Examples of GSM commands:
GSM/3G modems typically support the ETSI GSM 07.07/3GPP TS 27.007 AT command set extensions, although how many commands are implemented varies.
Most USB modem vendors, such as Huawei, Sierra Wireless, Option, have also defined proprietary extensions for radio mode selection (GSM/3G preference) or similar. Some recent high speed modems provide a virtual Ethernet interface instead of using a Point-to-Point Protocol (PPP) for the data connection because of performance reasons (PPP connection is only used between the computer and the modem, not over network). The set-up requires vendor-specific AT command extensions. Sometimes the specifications for these extensions are openly available, other times the vendor requires an NDA for access to these.
Voice command set
Modems with voice or answering-machine capabilities support a superset of these commands to enable digital audio playback and recording.
See also
- Access Point Name (APN)
- Command and Data modes (modem)
- ITU-T Recommendations:
- H.324 (video)
- T.31 (fax)
- Motorola Phone AT Commands
Notes and references
External links
- List of AT commands: Basic (Hayes), Extended, Proprietary
- Hayes AT Command Reference Manual
- A list of Hayes AT commands
- 3gpp.org, 3GPP AT command set for User Equipment
- Modem initialisation string
- Extended Hayes AT command parameters for SMS (dead)
- Determining your Class of Fax / Modem
- Openmoko: AT Commands
- Cell modem commands
- ITU Standard V.250
- AT Commands Reference Guide from Telit (dead)
Source of the article : Wikipedia